Files
maintenance-tools/maintenance_service_http_monitoring
Stéphan Sainléger c4d7e9b8a9
Some checks failed
pre-commit / pre-commit (pull_request) Failing after 6m50s
[IMP] maintenance_service_http_monitoring: auto-close request on service recovery
Previously, maintenance requests created on HTTP failures were never
automatically resolved. Operators had to close them manually, with no
traceability of when or why the request was closed.

This commit adds automatic resolution when a service returns HTTP 200
while an open maintenance request exists for it.

**Detection logic** (in ``cron_check_http_services``):

Before pass 1, the cron takes a snapshot of all services that currently
have an open (non-done) ``maintenance.request`` via
``http_maintenance_request``. After pass 1, services in that snapshot
that are now OK (``http_status_ok = True``) are identified as recovered
and passed to the new ``_close_http_maintenance_request()`` method.

**Closure logic** (new ``_close_http_maintenance_request`` method):

1. Finds the first ``maintenance.stage`` with ``done = True``.
   If none exists (misconfigured instance), the method is a no-op.
2. Moves the ``maintenance.request`` to that done stage via ``sudo()``
   to bypass ACL restrictions from the cron user context.
3. Posts a chatter note on the request as OdooBot (``base.partner_root``)
   using ``subtype_xmlid="mail.mt_note"`` (internal note, not a follower
   notification) indicating the service URL and that the closure was
   performed automatically by the monitoring cron.
4. Clears ``http_maintenance_request`` on the ``service.instance``,
   allowing a fresh request to be created if the service fails again.

**Tests** (2 new, 16 total):

- ``test_service_recovery_closes_request``: full end-to-end scenario —
  first cron run produces a KO request, second cron run with HTTP 200
  asserts the request is in a done stage, the chatter note mentioning
  the service URL exists, and ``http_maintenance_request`` is cleared.
- ``test_no_close_when_no_open_request``: calling
  ``_close_http_maintenance_request`` on a service with no open request
  is a no-op and does not raise.

**README**: "Automatic Maintenance Requests" section extended with the
recovery behaviour (done stage, OdooBot note, field cleared).
2026-06-15 18:03:31 +02:00
..

=================================== maintenance_service_http_monitoring

This module provides automated HTTP availability monitoring for services defined on maintenance equipment. It periodically checks the HTTP status of service URLs and automatically creates maintenance requests when services are detected as unavailable.

Key features:

  • Automated HTTP checks: Scheduled cron job checks all active services
  • Maintenance mode: Temporarily disable monitoring during planned maintenance
  • Automatic maintenance requests: Creates corrective maintenance requests when services fail HTTP checks
  • Status tracking: Records last HTTP status code and check date per service

Installation

Use Odoo normal module installation procedure to install maintenance_service_http_monitoring.

This module depends on:

  • maintenance
  • maintenance_server_data

Python dependencies: This module requires the requests library.

Configuration

Maintenance Mode Duration

By default, maintenance mode lasts 4 hours. To change this:

  1. Go to Settings > Technical > System Parameters
  2. Create or edit the parameter:
    • Key: maintenance_service_http_monitoring.maintenance_mode_duration
    • Value: Duration in hours (e.g., 8)

Cron Jobs

Two scheduled actions are installed:

  1. HTTP Service Monitoring: check all services

    • Runs every 15 minutes
    • Checks HTTP status of all active service instances with URLs
  2. HTTP Service Monitoring: deactivate expired maintenance mode

    • Runs every 15 minutes
    • Automatically disables maintenance mode when the end time is reached

Webhook Notifications

Go to Settings > Technical > Parameters > System Parameters and configure:

+--------------------------------------------------------+----------------------------------------+ | Key | Description | +========================================================+========================================+ | maintenance_service_http_monitoring.webhook_url | Webhook URL (POST endpoint) | +--------------------------------------------------------+----------------------------------------+ | maintenance_service_http_monitoring.webhook_user | Basic Auth username (optional) | +--------------------------------------------------------+----------------------------------------+ | maintenance_service_http_monitoring.webhook_password| Basic Auth password (optional) | +--------------------------------------------------------+----------------------------------------+

Usage

Monitoring Services

Services are automatically monitored if they have:

  • A service URL defined
  • An associated equipment
  • The equipment is not in maintenance mode
  • The service instance is active

The monitoring checks HTTPS availability (HTTP URLs are automatically upgraded to HTTPS). A service is considered OK if it returns HTTP 200.

Using Maintenance Mode

When performing planned maintenance on a server:

  1. Go to Maintenance > Equipments
  2. Open the equipment record
  3. Click "Activer le mode maintenance" (Activate maintenance mode)
  4. HTTP monitoring is suspended for this equipment
  5. The mode automatically expires after the configured duration
  6. Or click "Désactiver le mode maintenance" to end it manually

Viewing HTTP Status

On service instances, you can see:

  • Last HTTP Status Code: The last received HTTP status (200, 404, 500, etc.)
  • Last HTTP Check Date: When the last check was performed
  • HTTP Status OK: Quick visual indicator of service health

Automatic Maintenance Requests

When a service fails HTTP checks:

  • A corrective maintenance request is created per failing service, named [HTTP KO] {service_url}
  • The request description includes the error detail: the HTTP status code, or a network error label (timeout / DNS / SSL) when no HTTP response was received
  • No duplicate is created as long as an open request already exists for that service
  • A double-check is performed before creating the request: the service is retested after 2 seconds. A maintenance request is only created if the service fails both checks, reducing noise from transient HTTP errors

When a service recovers (returns HTTP 200 after having an open request):

  • The open maintenance request is automatically moved to the first done stage
  • A chatter note is posted on the request by OdooBot to record the automatic closure
  • The link between the service and the request is cleared, allowing a new request to be created if the service fails again in the future

Webhook notifications

When a new maintenance request is created (HTTP check failure), the module can send a webhook notification to an external service (e.g., n8n, Rocket.Chat, Slack).

The webhook sends a JSON POST with the following structure::

{
    "id": 42,
    "name": "[HTTP KO] Server Name",
    "priority": "2",
    "description": "Service KO: https://example.com",
    "equipment": "Server Name",
    "link": "https://odoo.example.com/web#id=42&model=maintenance.request&view_type=form"
}

Known issues / Roadmap

  • Add configurable alert thresholds (e.g., alert after N consecutive failures)
  • Add email/notification on service failure
  • Support custom HTTP check endpoints (e.g., /health)
  • Add support for basic authentication

Bug Tracker

Bugs are tracked on our issues website. In case of trouble, please check there if your issue has already been reported. If you spotted it first, help us smashing it by providing a detailed and welcomed feedback.

Credits

Contributors

  • Stéphan Sainléger

Funders

The development of this module has been financially supported by:

Maintainer

This module is maintained by Elabore.